C. Johnson, JTB Marine Service, 727.323.2500, www.jtbmarine.com
40
System Design:
Wiring
Considerations
•
For a sample calculation, assume the
following:
–
The maximum current will be 200 amps
–
The round trip from the B+ bus bar to the
inverter/charger and back to the B- bus is 18
feet
–
3% allowable voltage drop; 0.36
–
–